Select Page

PL516 Power Supply System

The PL516 is a high sophisticated, high density, programmable 16-channel with full  redundancy low-voltage power supply system. Using the remote monitoring and control features it can be used to supply a large numbers of external load- channels with high power consumption also over long distances.

Dynamic behavior is adjustable via software (long-medium-short sensed distances to loads). Voltages, Currents, temperatures and output power are programmed and controlled by the internal processor and illegal modes as well as failure will be detected.

The modular construction with a 19″rack mountable power bin and two plug-in power supply boxes..

Features

PL516 Features

  • Up to 2x 8 independent, potential free DC outputs, 250W /550W each, total up to 4 kW output power
  • Output channels with fully redundancy
  • Extremely low noise and ripple
  • Channels can be operated in Master-Slave mode for paralleling of two ore more outputs (current boosting).
  • Floating range: +/-100V (default, optimal for low noise). Can be increased up to +/- 500V
  • Programmable voltages and thresholds on voltages, currents and temperatures, ramp rates, fully controlled, programmable trip levels and action / group behavior, voltage or current controlled mode
  • Air cooled, self ventilated with over temperature protection
  • CE conform EN 50 081/82 part 1 (EN 50 022 B), safety in accordance with EN 60 950
  • Ethernet  and  USB  interfaces for remote monitoring and control, Web interface / SNMP
  • 94V – 265VAC world-wide auto-range AC input, with power factor correction / sinusoidal mains current EN 61000-3-2, CE
  • DC Output connections: bin with customized DC connectors including Sense and temperature sensor connections.
  • Dimensions: 19″ (430mm) x 3U (133mm) x 450mm [whd], weight: depending on the number of power modules

Ordering Information

Standard configurations (others possible by request).

PL516 consists of:

=> Power Bin: 19’’ bin, 3U for rack mounting, hosting two power boxes

=> Power Box: 1.5U, containing a PFC mains input module, a control card and slots for up to 4 modules (MEH type, single channel, 550W to 650W) for a maximum of 8 channels. The power box includes the Ethernet/USB combo card

=> Power Modules integrated into Power Box slots for a maximum of 4 modules / 16 channels

Standard MEH power modules

TypeOptimal Voltage rangeChannelsPeak output / Power
MEH – 02/072V … 7V1115A / 550W
MEH – 06/106V … 10V180A / 550W
MEH – 07/167V … 16V146A / 550W
MEH – 12/3012V … 30V123A / 550W
MEH – 30/6030V … 60V113,5A / 650W
MEH – 50/8550V … 85V18A / 650W

Standard MDH power modules

TypeOptimal Voltage rangeChannelsPeak output / Power
MDH – 02/052V … 5V2+/- 46A / 240W (480W total)
MDH – 02/072V … 7V2+/- 30A / 210W (420W total)
MDH – 07/167V … 16V2+/- 20A / 250W (500W total)
MDH – 07/247V … 24V2+/- 12A / 288W (576W total)
MDH – 30/6030V … 60V2+/- 6A / 250W (500W total)

Technical Information

Regulation (fast circuit for short sensed distance)

Static:

MEH 550W/650W  <15mV +/-100% load, +/- full mains range
MDH (20A) <0.05% +/-100% load, +/- full mains range
MDL, MDH <0.1% +/-100% load, +/- full mains range
Dynamic (0,5 m wire)
MEH, MDH <100mV +/-25% load
MDL, MDH <0.7% +/-25% load

Recovery time (0,5 m wire) +/-25% load within +/-1% deviation within +/-0.1% dev.
Modules 550W 0.2ms 0.5ms
Modules 650W >30V 0.5ms 1.0ms
MDL, MDH 0.0ms 1.0ms

Conditions: Current slope <1000A/ms, 20mF per 100A parallel to load

Regulation (slow circuit for long sensed distance)

Static:

MEH 550W/650W  <15mV +/-100% load, +/- full mains range
MDL, MDH  <0.05% +/-100% load, +/- full mains range

Dynamic deviation depends on current slope resp. filter capacitors at load side only


Recovery time (40 m wire) 5V at load side, V drop < 2V   within +/-10% deviation within +/-1% deviation
MEH, MDH <150ms 250ms
MDL <150ms 320ms

Regulation timing adaptable to dynamic conditions (induced by cable length, voltage drops, sinker and filter capacities at load side)

DC output characteristics  
Sense compensation range limited to < 10V or nom voltage (except special versions)
Sense mode closed loop and continuously controlling regulator to load
Floating Range PL508 >nominal output voltage for MEH,
min. +/-10V for voltage ranges < 7V MEH and MDL

Noise and ripple    
0.5 m wire  (< 7V) <10mV peak to peak  0-20 MHz
0.5 m wire  (> 7V) <15mV peak to peak 0-20 MHz
10 m wire  <3mV peak to peak 0-300 MHz

Conditions at load side: parallel (X) 330µF and 1µF ceramic, 100nF HF conducting to case (Y) each line

EMC compatibility  
EN 61 000-6-3:2001 [RF emission]
EN 55 022:1998 + Corr:2001 + A1:2000 Class B conducted noise
EN 55 022:1998 + Corr:2001 + A1:2000 Class B radiated noise
EN 61 000-3-2:2001 harmonics
EN 61 000-3-3:1995 +Corr:1997 +A1:2001 flicker
EN 61 000-6-2:2001 [immunity]
EN 61 000-4-6:1996 + A1:2001 injected HF currents
EN 61 000-4-3:1996 + A1:1998 + A2:2001 radiated HF fields, ”900MHz”
EN 61 000-4-4:1995 + A1:2001 burst
EN 61 000-4-5:1995 + A1:2001 surge
EN 61 000-4-11:1994 + A1:2000 voltage variations
EN 61 000-4-2:1995 + A1:1998 + A2:2001 ESD

Parameter  
Emission: CE EN 50081-1 (EN 55 022-B)
Immunity: CE EN 50082-1 or 2
Operation temperature:  0....50°C without derating, storage: -30°C till 85°C
Temperature coefficient: < 0.2% / 10K
Stability (condition const.): <5mV or 0.1% within 24 h, <25mV or 0.3% within 6 months
Current limiting: 100% of nominal values, programmable to lower values via Interface or display tableau. In case of overcurrent:
Ilim  defines a constant current level, if status Umin set to 0V for the concerned channel, Imax defines the global trip off setpoint independant of status voltage window
Voltage rise:  Monotone and synchron. 50ms ramping (factory settings), other slope and different timing programmable
Voltage set:  discharge of output capacitors after DC off. 
OV protection: Factory setting to 125% of nominal values
Status control:
DC Off (trip off):
within 3ms if >2% (default) deviation from nominal or programmed values , after overload, overheat (temperature limits 90/110°C heat sink, 70°C ambient), overvoltage, undervoltage , all trip off points processor controlled and programmable / disabling
DC Off / On,      channel wise By setting status Umin and output Voltage of selected channel both to  0V 
Interlock input: High level or open: All outputs DC off (optional feature)
Temperature limits: 90°C mains input, 110°C  modules (heat sink), 70°C ambient internal
Efficiency: Power module: 75% 2V/ -83% >5V/ -85% >12V/-90%  >48V    for 230VAC input voltage
M T B F: >65,000 h (blower), electronics > 100,000 h at 40°C ambient

 

Request a Quote

Learn how W-IE-NE-R products can add power, boost speed and bring rugged durability to your project.

  • This field is for validation purposes and should be left unchanged.