WIENER presents with Mpod a new, universal multi-channel low voltage (LV) and high voltage (HV) computer controlled power supply system. Offering highest channel density the MPOD mainframe can house up to 10 plug-in modules which results in 80 up to nearly 500 individually controlled channels per mainframe. Built in a modular way MPOD consists of the mainframe / bin, a front side plug-in controller with Ethernet and USB ports, a fan tray and a power supply which is located in the back.

In order to tailor the system to individual hardware needs MPOD can be configured as “low-voltage only”, “high voltage only” or “mixed configuration”. Further the MPOD mainframe is configurable to have all LV / HV connectors either on the front or rear side. Different control and monitoring options are offered. The MPOD controller with a interfaces for 10/100 Ethernet, CAN bus and USB-2 provides a variety of network capabilities. Local control is available by using the optional LCD display.

Features

Mpod Features

  • 19″ rack mountable bin with module cage for 10 LV or HV modules, compact design with ruggedized mechanics
  • Two mounting modes:  outputs at front- or at rear side
  • 8U bin for bottom cooling air intake, optional with internal dust filter
  • Modular design: fan tray and primary power supply easily removed
  • Module size 6U x 8PU, 220mm deep
  • LV and HV modules freely mixable
  • High Voltage modules (ISEG) with 8 … 48 channels of 500V … 20kV, floating or common ground, low noise and ripple, up to 480 HV channels per mainframe possible
  • Low Voltage modules (WIENER) with 8 channels in 0-8V … 0 – 120V ranges, up to 50W/channel max., low noise and ripple
  • Lowest noise and ripple
  • High precision / resolution for monitoring and setting
  • Mpod Controller with Ethernet, CAN-bus, USB interface, and interlock input, TCP/IP with Web-server and SNMP protocol, optional with ISEG CC24 controller (linux OS with iCS web service, EPIC’s IOC, OPC and SNMP)
  • Primary power supply based on UEP6021 technology, low noise / high reliability design
  • 94V – 265VAC world-wide auto-range AC input, with power factor correction, CE
  • Graphic display for local monitoring and programming with dual rotary/push- buttons (optional)
  • Dimensions: 19” x 460mm (depth) x 8U (bottom air intake) or 9U (front air intake)
  • Weight: ca. 20 kg, depending on options

Ordering Information

Standard configurations (others possible by request).

TypeGraphic displaySlotsPrimary HV-powerOutputBackplane
Mpod EC-10600WFrontHV/LV
Mpod EC-R-10600WRearHV/LV
Mpod LXLCD10600WFrontHV/LV
Mpod LX-RLCD10600WRearHV/LV
Mpod EC LV-10-FrontLV
Mpod EC LV-R-10-RearLV
Mpod EC HV-10600WFrontHV
Mpod EC HV-R-10600WRearHV
Mpod LX LVLCD10-FrontLV
Mpod LX LV-RLCD10-RearLV
Mpod LX HVLCD10600WFrontHV
Mpod LX HV-RLCD10600WRearHV
Mpod 2H-101200WFrontHV
Mpod 2H-R-101200WRearHV
Mpod 2H LXLCD101200WFrontHV
Mpod 2H LX-RLCD101200WRearHV

Technical Information

Specs:
Rated mains input range106- 230VAC ± 15% (90...265VAC)
Rated input currentSinusoidal 16A for suffix H input, 32A for suffix K input
Inrush current:limited to rated input current (cold unit)
Input fuse:external, internal on request
Isolation (Inp.- outp.)CE EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950
DC output power: 600 ... <3000W (92 …265VAC)  / 300W for MPOD micro
 
EMC Compatibility
EMA.EN 61 000-6-3:2001[RF emission]
EN 55 022:1998 + Corr:2001 + A1:2000  Class Bconducted noise
EN 55 022:1998+ Corr:2001 + A1:2000  Class Bradiated noise
EN 61 000-3-2:2001harmonics
EN 61 000-3-3:1995 +Corr:1997 +A1:2001flicker
EMBEN 61 000-6-2:2001 [immunity]
EN 61 000-4-6:1996 + A1:2001injected HF currents
EN 61 000-4-3:1996 + A1:1998 + A2:2001radiated HF fields  incl. ”900MHz”
EN 61 000-4-4:1995 + A1:2001Burst
EN 61 000-4-5:1995 + A1:2001Surge
EN 61 000-4-11:1994 + A1:2000voltage variations
EN 61 000-4-2:1995 + A1:1998 + A2:2001ESD
 
Operation temperature: 0… 50°C  ambient without derating,  Storage:-30°C ... +85°C
Temperature coefficient:< 0,2% / 10K
Stability: 10mV or 0,1%  /  24 hours, 25mV or 0,3%  /   6 month
(under constant conditions)
Current limits:adjustable to any lower level
Voltage rise characteristics: monotonic 50ms, processor controlled.
Overvoltage protection:crow bar protection trip off adjusted to 125% of nominal voltage  each output
DC Off (trip off):  within 5ms if >5% deviation from adjusted nominal values, after overload, overheat, overvoltage, undervoltage (bad status), and fan fail, if temperatures exceed 125°C at heat sinks Limits programmable. Outputs discharged by crow bars, when power supply tripped- or switched Off.
Efficiency:75% ... 85%, depends on used modules
M F O T (Maintenance Free Operation Time):
internal blowers:40°C ambient>65 000 h
25°C ambient100 000 h
electronics:40°C ambient>100 000 h
 

Request a Quote

Learn how W-IE-NE-R products can add power, boost speed and bring rugged durability to your project.

  • This field is for validation purposes and should be left unchanged.