PL512 Power Supply System
The PL 512 is a high sophisticated, high density, programmable 12-channel floating low-voltage power supply system. Using the remote monitoring and control features either via USB or Ethernet it can be used to supply external load-channels with high power consumption also over long distances. Up to 3kW (3Ubox) DC output power can be provided.
Voltages, currents, temperatures and output power are programmable and controlled by the internal processor. Illegal modes as well as failure conditions will be detected. Dynamic behavior is programmable via USB port (long-moderate-short sensed distances to loads).
The modular construction with a 19″ rack mountable power bin and a plug-in power supply box allows to swap the power supply without any tools and within shortest time.
Features
PL512 Features
- Up to 12 independent, potential free DC outputs, 250W each, total up to 3 kW output power
- Extremely low noise and ripple
- Channels can be operated in Master-Slave mode for paralleling of two ore more outputs (current boosting).
- Floating range: +/-100V (default, optimal for low noise). Can be increased up to +/- 500V
- Programmable voltages and thresholds on voltages, currents and temperatures, ramp rates, fully controlled, programmable trip levels and action / group behavior , voltage or current controlled mode
- Air cooled, self ventilated with over temperature protection
- CE conform EN 50 081/82 part 1 (EN 50 022 B), safety in accordance with EN 60 950
- Ethernet and USB interfaces for remote monitoring and control, Web interface / SNMP
- 94V – 265VAC world-wide auto-range AC input, with power factor correction / sinusoidal mains current EN 61000-3-2, CE
- DC Output connections: 4mm (M4-80A), Sense and temperature sensor connections: 9 pin Sub D female connector for 2 channels, senses wired to terminals on rear side.
- Optional alphanumeric display
- Optional with Power fail- and System Reset- Signal
- Optional with Interlock input
- Optional direct water cooling with same size as air cooled ones
- Dimensions: 430mm x 3U (133mm) x 325mm [whd], weight: from 9.6 to 19 kg depending on the number of power modules
Ordering Information
Standard configurations (others possible by request).
PL512 consists of:
=> Power Bin: 19’’ bin for rack mounting hosting a power box
Type | Dimensions | Features |
---|---|---|
PBN512 – 3U RASO | 3U x 19’’ x 445mm | Folded metal frame |
PBN512 – 4U | 4U x 19’’ x 445mm | Aluminum side panels |
=> Power Box containing a PFC mains input module, a control card and slots for up to 6 modules (MDH/MDL types, dual channel, 250W) for a maximum of 12 channels. The power box includes the Ethernet/USB combo card and can be outfitted with an optional display (EX version) as well as individual channel interlock feature (I option)
PL512 Power Box for insertion in Power Bin :
Type | Dimensions | Features |
---|---|---|
PBX512 | 3U x 19’’ x 445mm | Ethernet, USB, “Easy Lever” extraction mechanism |
PBX506 – EX | 3U x 19’’ x 445mm | Display, Ethernet, USB, “Easy Lever” extraction mechanism |
=> Power Modules integrated into Power Box for a maximum of 6 modules / 12 channels
Type | Optimal Voltage range | Channels per module | Peak output / Power | ||
---|---|---|---|---|---|
MDH – 02/05 | 2V … 5V | 2 | +/- 46A / 240W (480W total) | ||
MDH – 02/07 | 2V … 7V | 2 | +/- 30A / 210W (420W total) | ||
MDH – 07/16 | 7V … 16V | 2 | +/- 23A / 250W (500W total) | ||
MDH – 07/24 | 7V … 24V | 2 | +/- 11,5A / 275W (550W total) | ||
MDH – 12/30 | 12V … 30V | 2 | +/- 12A / 288W (576W total) | ||
MDH – 30/60 | 30V … 60V | 2 | +/- 6A / 250W (500W total) |
Standard MDH/MDL power modules (up to 6)
Technical Information
Regulation (fast circuit for short sensed distance) | ||
---|---|---|
Static: | ||
MEH 550W/650W | <15mV | +/-100% load, +/- full mains range |
MDH (20A) | <0.05% | +/-100% load, +/- full mains range |
MDL, MDH | <0.1% | +/-100% load, +/- full mains range |
Dynamic (0,5 m wire) | ||
MEH, MDH | <100mV | +/-25% load |
MDL, MDH | <0.7% | +/-25% load |
Recovery time (0,5 m wire) +/-25% load | within +/-1% deviation | within +/-0.1% dev. |
---|---|---|
Modules 550W | 0.2ms | 0.5ms |
Modules 650W >30V | 0.5ms | 1.0ms |
MDL, MDH | 0.0ms | 1.0ms |
Conditions: Current slope <1000A/ms, 20mF per 100A parallel to load
Regulation (slow circuit for long sensed distance) | ||
---|---|---|
Static: | ||
MEH 550W/650W | <15mV | +/-100% load, +/- full mains range |
MDL, MDH | <0.05% | +/-100% load, +/- full mains range |
Dynamic deviation depends on current slope resp. filter capacitors at load side only |
Recovery time (40 m wire) 5V at load side, V drop < 2V | within +/-10% deviation | within +/-1% deviation |
---|---|---|
MEH, MDH | <150ms | 250ms |
MDL | <150ms | 320ms |
Regulation timing adaptable to dynamic conditions (induced by cable length, voltage drops, sinker and filter capacities at load side)
DC output characteristics | |
---|---|
Sense compensation range | limited to < 10V or nom voltage (except special versions) |
Sense mode | closed loop and continuously controlling regulator to load |
Floating Range PL508 | >nominal output voltage for MEH, min. +/-10V for voltage ranges < 7V MEH and MDL |
Noise and ripple | ||
---|---|---|
0.5 m wire (< 7V) | <10mV peak to peak | 0-20 MHz |
0.5 m wire (> 7V) | <15mV peak to peak | 0-20 MHz |
10 m wire | <3mV peak to peak | 0-300 MHz |
Conditions at load side: parallel (X) 330µF and 1µF ceramic, 100nF HF conducting to case (Y) each line
EMC compatibility | |
---|---|
EN 61 000-6-3:2001 | [RF emission] |
EN 55 022:1998 + Corr:2001 + A1:2000 Class B | conducted noise |
EN 55 022:1998 + Corr:2001 + A1:2000 Class B | radiated noise |
EN 61 000-3-2:2001 | harmonics |
EN 61 000-3-3:1995 +Corr:1997 +A1:2001 | flicker |
EN 61 000-6-2:2001 | [immunity] |
EN 61 000-4-6:1996 + A1:2001 | injected HF currents |
EN 61 000-4-3:1996 + A1:1998 + A2:2001 | radiated HF fields, ”900MHz” |
EN 61 000-4-4:1995 + A1:2001 | burst |
EN 61 000-4-5:1995 + A1:2001 | surge |
EN 61 000-4-11:1994 + A1:2000 | voltage variations |
EN 61 000-4-2:1995 + A1:1998 + A2:2001 | ESD |
Parameter | |
---|---|
Emission: | CE EN 50081-1 (EN 55 022-B) |
Immunity: | CE EN 50082-1 or 2 |
Operation temperature: | 0....50°C without derating, storage: -30°C till 85°C |
Temperature coefficient: | < 0.2% / 10K |
Stability (condition const.): | <5mV or 0.1% within 24 h, <25mV or 0.3% within 6 months |
Current limiting: | 100% of nominal values, programmable to lower values via Interface or display tableau. In case of overcurrent: Ilim defines a constant current level, if status Umin set to 0V for the concerned channel, Imax defines the global trip off setpoint independant of status voltage window |
Voltage rise: | Monotone and synchron. 50ms ramping (factory settings), other slope and different timing programmable |
Voltage set: | discharge of output capacitors after DC off. |
OV protection: | Factory setting to 125% of nominal values |
Status control: DC Off (trip off): | within 3ms if >2% (default) deviation from nominal or programmed values , after overload, overheat (temperature limits 90/110°C heat sink, 70°C ambient), overvoltage, undervoltage , all trip off points processor controlled and programmable / disabling |
DC Off / On, channel wise | By setting status Umin and output Voltage of selected channel both to 0V |
Interlock input: | High level or open: All outputs DC off (optional feature) |
Temperature limits: | 90°C mains input, 110°C modules (heat sink), 70°C ambient internal |
Efficiency: | Power module: 75% 2V/ -83% >5V/ -85% >12V/-90% >48V for 230VAC input voltage |
M T B F: | >65,000 h (blower), electronics > 100,000 h at 40°C ambient |