MPOD Micro-1 Crate
The Mpod micro-1 crate is the smallest and lowest cost option for the WIENER multi-channel high and low voltage power supply system. The Mpod micro mainframe can house one plug-in low or high voltage modules in addition to the Mpod controller which provides10/100 Ethernet, CAN bus and USB-2 interfaces.
High voltage modules are available with 8 up to 48 channels in the voltage range of 500V … 20kV. All low voltage modules have 8 channels with a maximum of 50W / channel in different voltage ranges. All HV and LV channels are individually controlled and monitored.
The new re-designed chassis provides improved mechanical construction together with better cooling air flow and allows optionally local display and control.
Features
- 19″ x 1.5U micro bin with module cage for 1 LV or HV module, can be used as desktop, micro tower or rack mountable
- 1 slot for LV and / or HV modules
- New, redesigned mechanics for 19″ rack or table top operation
- Up to 48 channels high voltage possible, ISEG EHS/EDS/EBS modules with 8 … 48 channels in a range of 100V up to 20kV, floating or common ground
- Up to 8 channels low voltage per chassis, WIENER MPV 8xxx series 8-channel low voltage modules in 0…8V up to 0….120V ranges
- built in primary power supply (600W LV, 100W HV), low noise and ripple
- integrated cooling fan, with side to side air flow and integrated air filter
- Optional with display and local control
- Mpod controller card with Ethernet 10/100, CAN-bus and USB-2 interfaces, Interlock connector, optional with ISEG CC24 controller (linux OS with iCS web service, EPIC’s IOC, OPC and SNMP)
- Integrated web-server and TCP/IP communication via SNMP, OPC server, DHCP capable
- 94V – 265V world-wide auto-range AC input, with power factor correction, CE-conformity
- Dimensions: 19” (482mm) x 1.5U (178mm) x 480mm [whd], weight: ca. 10 kg
Ordering Information
Standard configurations (others possible by request).
Type | Graphic display | Slots | Primary HV-power | Output | Backplane |
---|---|---|---|---|---|
Mpod Micro-1 | No | 1 | 300W | Front / Rear | HV/LV |
Mpod Micro-1-LX | Yes | 1 | 300W | Front / Rear | HV/LV |
Mpod Micro-1-HV | No | 1 | 300W | Front / Rear | HV |
Mpod Micro-1-HV-LX | Yes | 1 | 300W | Front / Rear | HV |
Mpod Micro-1-LV-LX | Yes | 1 | - | Front / Rear | LV |
Mpod Micro-1-LV | No | 1 | - | Front / Rear | LV |
Technical Information
Specs: | |
---|---|
Rated mains input range | 106- 230VAC ± 15% (90...265VAC) |
Rated input current | Sinusoidal 16A for suffix H input, 32A for suffix K input |
Inrush current: | limited to rated input current (cold unit) |
Input fuse: | external, internal on request |
Isolation (Inp.- outp.) | CE EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950 |
DC output power: | 600 ... <3000W (92 …265VAC) / 300W for MPOD micro |
EMC Compatibility | ||
---|---|---|
EMA. | EN 61 000-6-3:2001 | [RF emission] |
EN 55 022:1998 + Corr:2001 + A1:2000 Class B | conducted noise | |
EN 55 022:1998+ Corr:2001 + A1:2000 Class B | radiated noise | |
EN 61 000-3-2:2001 | harmonics | |
EN 61 000-3-3:1995 +Corr:1997 +A1:2001 | flicker | |
EMB | EN 61 000-6-2:2001 | [immunity] |
EN 61 000-4-6:1996 + A1:2001 | injected HF currents | |
EN 61 000-4-3:1996 + A1:1998 + A2:2001 | radiated HF fields incl. ”900MHz” | |
EN 61 000-4-4:1995 + A1:2001 | Burst | |
EN 61 000-4-5:1995 + A1:2001 | Surge | |
EN 61 000-4-11:1994 + A1:2000 | voltage variations | |
EN 61 000-4-2:1995 + A1:1998 + A2:2001 | ESD |
Operation temperature: | 0… 50°C ambient without derating, Storage:-30°C ... +85°C | |
Temperature coefficient: | < 0,2% / 10K | |
Stability: | 10mV or 0,1% / 24 hours, 25mV or 0,3% / 6 month | |
(under constant conditions) | ||
Current limits: | adjustable to any lower level | |
Voltage rise characteristics: | monotonic 50ms, processor controlled. | |
Overvoltage protection: | crow bar protection trip off adjusted to 125% of nominal voltage each output | |
DC Off (trip off): | within 5ms if >5% deviation from adjusted nominal values, after overload, overheat, overvoltage, undervoltage (bad status), and fan fail, if temperatures exceed 125°C at heat sinks Limits programmable. Outputs discharged by crow bars, when power supply tripped- or switched Off. | |
Efficiency: | 75% ... 85%, depends on used modules | |
M F O T (Maintenance Free Operation Time): | ||
internal blowers: | 40°C ambient | >65 000 h |
25°C ambient | 100 000 h | |
electronics: | 40°C ambient | >100 000 h |
Similar Products