6U VXI-C size 4600 RR Crate Series
Designed for high performance automated test and scientific applications. The-RR VXI mainframe series (RR=cooling intake and exhaust at rear side), takes advantage of WIENER’s 50-years experience as a leading manufacturer of powered crates for scientific research and industry.
The 4600 series is a compact design with high density, highly sophisticated modular designed power supplies. The power supply features medium output power up to 3kW, with extremely low noise and ripple (PARD). The 8U, 13-slot chassis offers superior cooling, due to an efficient air guiding system. The fan tray has three high efficient DC-fans, situated at the lower rear side in a removable fan tray with optional air filter.
Different power supply configurations as well as a variety of crate options are offered.
Features
UEV 4600 VXI-C Bin
- 19” x 8U enclosure for 13 VXI modules 6U x 340mm
- Very rugged steel-aluminum construction features 5mm thick heavy duty side plates with zero-tolerance countersink screw positioning of all horizontal rails
- Optional with side extensions for receiver card mounting
- Monolithic 13 slot VXI or VXI-4 backplane (J1/J2), 8 layer PCB, active termination and active automatic-daisy-chain
- 1U air compression chamber below the VXI module card cage
- 1U air exhaust above VXI module card cage
- WIENER Shelf Manager for local and remote monitoring and control, monitors and controls power supply , fan, remote on/off, SYSRES, thermal monitoring
- Alphanumeric high-visibility LED display, switches, I/O and Ethernet / RS232 ports on front top panel
- Optional up to 8 temperature sensors in VME card cage above modules
- Dimensions: 19” x 8U x 480mm [whd], weight: ca.15 kg
UEL 4600 Fan Tray
- Designed to provide efficient cooling of C-size VXI modules
- Cooling capacity of 2kW optionally up to 2.6kW
- High efficient 3- channel air guiding system
- 3 high efficiency / high RPM long-live DC muffin fans situated in a 3U fan tray at lower rear side.
- Individual fan speed and thermal monitoring, adjustable fan speed (1200 … 6100 RPM)
- Optional with air filter
- Dimensions: 430mm x 3U x 250mm [whd], weight: ca.8 kg
UEP 6021 Power Supply
- High density power supply in WIENER “Cavity-VHF” switching technology with excellent RF-shielding, optionally ultra low noise < 3mVpp (all voltages <12V), other rails <10mVpp
- Modular and expandable design with self-ventilated universal power blocks, individually sensed and floating DC outputs
- Micro-processor controlled, programmable voltage adjustment, current limits and over-/ under voltage trip off points, temperature limits
- Self protected against any failure as under/over voltage, over current, over temperature, etc
- 94V – 260V world-wide auto-range AC input, with power factor correction, CE-conformity
- High power density, up to 3 kW/6kW DC output power for 3U or 6U high power box
- Dimensions: 430mm x 3U (133mm) x 250mm [whd], weight: from 15 to 19 kg, depending on the number of power modules
Ordering Information
Standard configurations (others possible by request).
Crate Version | Backplane | +5V | +12V | -12v | -5.2V | -2V | +24V | -24V | Height |
---|---|---|---|---|---|---|---|---|---|
VXI 4600 RR631 | VXI | 115A | 23A | 23A | 45A | 45A | 15A | 15A | 3U |
VXI 4600 RR634 | VXI | 115A | 23A | 23A | 115A | 115A | 15A | 15A | 3U |
VXI 4600 RR635 | VXI | 115A | 45A | 45A | 45A | 45A | 15A | 15A | 3U |
VXI 4600 RR641 | VXI | 230A | 23A | 23A | 45A | 45A | 15A | 15A | 3U |
Technical Information
UEV 4600 VXI bin
The 4600 bin has a 2U high fan tray space below the front and optional rear card cages for the UEL6020 fan tray. The total height of the 6021 bin is 8U.
The power supply is plugged into the top rear position. For this purpose the DC power terminal is located behind the backplane / top connector row.
The 6000 series crates offer excellent electrical safety, i.e. no AC mains wiring is inside the bin and fan tray. All power comes from well-isolated DC low voltages (EN60950, UL1950). A Power Protect Memory (PPM) further protects the crate by preventing incompatible power supplies from powering up.
Dimensions of 6021 standard crates (depth: +25mm for inserted power supply)
- 1U air compression chamber below the VXI module card cage
- 1U air exhaust above VXI module card cage
- WIENER Shelf Manager for local and remote monitoring and control, monitors and controls power supply , fan, remote on/off, SYSRES, thermal monitoring
- Alphanumeric high-visibility LED display, switches, I/O and Ethernet / RS232 ports on front top panel
- Optional up to 8 temperature sensors in VME card cage above modules
- Dimensions: 19” x 8U x 480mm [whd], weight: ca.15 kg
6U VXI backplane
Hartmann Elektronik monolithic multi-layer 13 slot VXI bus with active automatic daisy chain and passive or active termination. Outfitted with 96pin DIN J1/J2 connectors as per VXI specification:
Power per slot | VXI C size | VXI D size |
---|---|---|
( at 20°C / 70°C) | 13 slot J1/J2 | 13 slot J1/J2/J3 |
5V | 14A / 10.5A | 24A / 18A |
+/-12V | 2A / 1,5A | 4A / 3A |
-5,2V | 10A / 7.5A | 20A / 15A |
-2V | 4A / 3A | 10A / 7.5A |
+/-24V | 2A / 1.5A | 4A / 3A |
Layers | 8 | 10 |
UEL6020 Fan Tray / Control Interface
The UEL6020 is the plug in fan and control unit for all crates of the 6000 family. Matching the crate card cage size fan trays are available in 160mm, 220mm, 340mm, 400mm and 600mm depth. In addition to providing a cooling airflow through the front card cage optionally rear side transition board cooling is possible. All UEL 6020 fan trays are outfitted with long life individually controlled DC fans for bottom to top air flow operation. Depending on the required air flow and crate size either “standard” or “super blower” fans are used. All fan trays (except the 6U / 160mm fan tray for frontal entry) are equipped with a topped plenum pressure chamber, 25mm high, for optimized air flow homogenization through all slots as well as for mixed module depths. UEL 6020 fan trays have a built-in microprocessor for fan control, communication with the power supply and display / networking. Default version is the EX type which has a high visibility alphanumeric display and Ethernet interface for remote monitoring and control. This interface allows the crate, including power supply, fan tray and bin temperature sensors, to be controlled and monitored remotely using Ethernet. A built in web server allows the crate health to be monitored via a web browser on a PC attached to the appropriate network, while SNMP provides a convenient way to tailor a control system to a given application. All network connectors are RJ45 type.Standard 118mmx118mm | Super Blower 150mm | HRPM 118mm x 118mm | |
---|---|---|---|
Static pressure at 3000 RPM: | 8 mm H2O column | 14 mm H2O column | 28 mm H2O column |
Max. Speed of Rotation: | >3000 RPM | >3000 RPM | >6000 RPM |
Power Consumption | 6-8W typical | 12-15W Typical | 20W |
Start up Current: | Limited by soft start circuit | ||
Operating Voltage: | Fan tray 30VDC, internal Blowers 0-24VDC, | ||
Optimum operating range: | 2- 3,8mm H2O | 4- 5,5mm H2O | 10- 15mm H2O |
Operating Temperature: | 0... 70°C | ||
MFOT (Maintenance Free Operation Time) | >65 000 h at 40°C ambient, > 85 000 h at 25°C ambient |
Status | Green: | all values inside tolerance |
Fan fail | Yellow: | one or more fans fail |
Overheat | Yellow: | power supply overheated |
Sys fail | Red: | VMEbus generates sysfail |
UEP 6021 Power Supplies
High density, highly sophisticated modular power supplies designed with WIENER's "Low-Noise-Cavity-VHF-switching technology" which features extremely low ripple and noise (PARD) figures. This technology prevents uncontrolled RF emissions by proper internal shielding and containing of switching parts as well as an efficient deflection of magnetically induced RF currents. A well-balanced thermal design secures excellent long term stability and high MTBF.
Up to eight independent regulated DC outputs. For higher current capability, power modules can work in parallel. All outputs are floating. Therefore common- or separated grounds can be realized at backplane level (for example analog- and digital- grounds isolated). Wide compatibility ranges become possible by automatic programming of voltage levels and current limits to reference-values that are stored in a bin-memory (Power Protection Memory, PPM system). Incompatibility between bin/backplane and power supply prompts the PPM to keep the power supply off.
Two types of power boxes are available: 3U box with 92-265VAC input for 1kW-3kW DC-output. 6U boxes offer space for a second A/C mains input (PFC) to utilize up to 6kW DC performance (230VAC mains input!). Power boxes include:
- Mains filter in connection with a power factor corrected mains input module (PFC) and soft start circuit,
- auxiliary power supply to provide monitoring and control logic as well as provide power for the fan tray,
- Monitoring and alarm circuit supported by a self-calibrating microprocessor system.
- Five, six (3U box) or 10 slots (6U box) for power modules (DC-to-DC converters)
- CAN-bus interface, processing all power supply, fan tray, and bin data
- Power modules and mains inputs are equipped with long life cooling fans.
Serial connections between power supply, fan tray and bin (plug & play) allows communication and exchange of data between all crate.
Rated mains input range | 106- 230VAC ± 15% (90...265VAC) |
Rated input current | Sinusoidal 16A for suffix H input, 32A for suffix K input |
Inrush current: | limited to rated input current (cold unit) |
Input fuse: | external, intern on special request |
Isolation (Inp.- outp.) | CE EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950 |
DC output power: | H for 1000... <3000W (92 …265VAC) K for 2000... <6000W (92 …265VAC) |
H input outfitted with removable power cord (3*1,5mm2) for 16A nominal input current, |
Regulation | |||
---|---|---|---|
Regulation static: | MEH 550W/650W | <15mV | (+/-100% load, +/- full mains range) |
MDH (20A): | <0,05% | (+/-100% load, +/- full mains range) | |
MDL / MDH | <0,1% | (+/-100% load, +/- full mains range) | |
Regulation dynamic: | MEH, MDH | <100mV | (+/-25% load) |
MDL / MDH | <0,7% | (+/-25% load) | |
Recovery time | +/-25% load: | within +-1% within +-0,1% | |
Modules 550W | 0,2ms | 0,5ms, | |
Modules 650W | 0,5ms | 1,0ms | |
MDL / MDH | 0,0ms | 1,0ms | |
(Conditions: Current slope <1000A/ms, 21mF per 100A ^ 1mF per slot) | |||
Sense compensation range: | difference between min. and max. output voltage |
Available modules
Type | Channels | Voltage range | Peak output / power | Noise and ripple |
---|---|---|---|---|
MEH | 1 | 2... 7,0V | 115A / 550W | 10mVpp, (0-20MHz ), <2mVrms (0-30MHz |
MEH | 1 | 7...16V | 46A / 550W | <15mVpp, (0-20MHz ), <2mVrms (0-30MHz) |
MEH | 1 | 12...30V | 23A / 550W | <15mVpp, (0-20MHz ), <2mVrms (0-30MHz) |
MEH | 1 | 30...60V | 13,5A / 650W | <15mVpp, (0-20MHz ), <2mVrms (0-30MHz) |
MDH | 2 | 2...7,0V | (+/-) 30A / 210W (420W) | <15mVpp, (0-20MHz ), <2mVrms (0-30MHz) |
MDH | 2 | 7...16V | (+/-) 20A / 250W (500W) | <15mVpp, (0-20MHz ), <2mVrms (0-30MHz) |
MDL | 2 | 7...24V | (+/-) 11,5A / 275W.(550W) | <15mVpp, (0-20MHz ), <2mVrms (0-30MHz) |
EMC Compatibility | ||
---|---|---|
EMA. | EN 61 000-6-3:2001 | [RF emission] |
EN 55 022:1998 + Corr:2001 + A1:2000 Class B | conducted noise | |
EN 55 022:1998+ Corr:2001 + A1:2000 Class B | radiated noise | |
EN 61 000-3-2:2001 | harmonics | |
EN 61 000-3-3:1995 +Corr:1997 +A1:2001 | flicker | |
EMB | EN 61 000-6-2:2001 | [immunity] |
EN 61 000-4-6:1996 + A1:2001 | injected HF currents | |
EN 61 000-4-3:1996 + A1:1998 + A2:2001 | radiated HF fields incl. "900MHz" | |
EN 61 000-4-4:1995 + A1:2001 | Burst | |
EN 61 000-4-5:1995 + A1:2001 | Surge | |
EN 61 000-4-11:1994 + A1:2000 | voltage variations | |
EN 61 000-4-2:1995 + A1:1998 + A2:2001 | ESD |
Operation temperature: | 0… 50°C ambient without derating, Storage:-30°C ... +85°C |
Temperature coefficient: | < 0,2% / 10K |
Stability: | 10mV or 0,1% / 24 hours, 25mV or 0,3% / 6 month (under constant conditions) |
Current limits: | adjustable to any lower level |
Voltage rise characteristics: | monotonic 50ms, processor controlled. |
Overvoltage protection: | crow bar protection trip off adjusted to 125% of nominal voltage each output |
DC Off (trip off): | within 5ms if >5% deviation from adjusted nominal values, after overload, overheat, overvoltage, undervoltage (bad status), and fan fail, if temperatures exceed 125°C at heat sinks Limits programmable. Outputs discharged by crow bars, when power supply tripped- or switched Off. |
Efficiency: | 75% ... 85%, depends on used modules |
M F O T | (Maintenance Free Operation Time): |
internal blowers: | 40°C ambient >65 000 h |
25°C ambient 100 000 h | |
electronics: | 40°C ambient >100 000 h |
Water cooled power supplies: | 40°C water >100 000 h |