Select Page

VXI-C size 165 Mini

The VXI165 mini crate is the perfect choice for small setups with only a few VXI instruments. The chassis offers 6 VXI slots in a compact designed chassis with integrated low noise power supply and cooling fan. The mini crate can be used on the desk either as a desktop or up-right unit or be installed in a 19” rack.

Based on the 6000 series it has a built-in microprocessor controlled low-noise power supply technology and provides all local and remote monitoring and control features.

Features

  • VXI-MINI-Bin mechanics for 6U x 340mm (C-size) VXI modules, suitable either for 19″ racks, as tower- or desktop box
  • 6 slot monolithic backplane VXI
  • Micro-processor controlled with alphanumeric high-visibility LED display, 4 status LED’s
  • Efficient DC blower, adjustable speed (1200 … 3200 RPM)
  • Integrated fan and thermal monitoring ( 8 temperature sensor ports, 5 ports free for custom applications) with temperature display (C/F), programmable over temperature protection
  • Ethernet  interface  for crate remote monitoring and control
  • Built-in power supply designed in low noise VHF switching technology, noise and ripple typically less than 10mV(pp) or 3mV(rms) , CE-conformity
  • 94V – 265V world-wide auto-range AC input, with power factor correction, CE-conformity
  • Dimensions: 19” (482mm)  x 5U (178mm) x 480mm [whd], weight: ca. 25 kg

Ordering Information

Standard configurations (others possible by request).

Crate VersionBackplane+5V+12V-12v-5.2V-2V+24V-24VHeight
VXI 165VXI45A11.5A11.5A45A22A13A13A5U
VXI 165 SpecialVXI115A23A23A45A22A13A13A5U

Technical Information

VXI Mini crate 165

Specs:  
Rated mains input range 106- 230VAC ± 15% (90...265VAC)
Rated input current Sinusoidal 16A
Inrush current: limited to rated input current (cold unit)
Input fuse: external,
Isolation (Inp.- outp.) CE EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950

DC output power: 650... <1100W (92…265VAC)
Regulation    
static: MDH (>20A) <0,05%      (+/-100% load, +/- full mains range)
  MDL / MDH <0,1%        (+/-100% load, +/- full mains range)
dynamic: MDH <100mV     (+/-25% load)
  MDL / MDH <0,7%        (+/-25% load)
Recovery time +/-25% load: within +-1%       within +-0,1%
Modules 550W    0,2ms  0,5ms, 
Modules 650W    0,5ms  1,0ms
MDL / MDH    0,0ms  1,0ms

(Conditions: Current slope <1000A/ms, 21mF per 100A ^ 1mF per slot)

Sense compensation range: difference between min. and max. output voltage

EMC Compatibility
EMA. EN 61 000-6-3:2001 [RF emission]
  EN 55 022:1998 + Corr:2001 + A1:2000  Class B conducted noise
  EN 55 022:1998+ Corr:2001 + A1:2000  Class B radiated noise
  EN 61 000-3-2:2001 harmonics
  EN 61 000-3-3:1995 +Corr:1997 +A1:2001 flicker
EMB EN 61 000-6-2:2001  [immunity]
  EN 61 000-4-6:1996 + A1:2001 injected HF currents
  EN 61 000-4-3:1996 + A1:1998 + A2:2001 radiated HF fields  incl. ”900MHz”
  EN 61 000-4-4:1995 + A1:2001 Burst
  EN 61 000-4-5:1995 + A1:2001 Surge
  EN 61 000-4-11:1994 + A1:2000 voltage variations
  EN 61 000-4-2:1995 + A1:1998 + A2:2001 ESD

Operation temperature: 0… 50°C  ambient without derating,  Storage:-30°C ... +85°C
Temperature coefficient: < 0,2% / 10K
Stability: 10mV or 0,1%  /  24 hours, 25mV or 0,3%  /   6 month
(under constant conditions)
Current limits: adjustable to any lower level
Voltage rise characteristics: monotonic 50ms, processor controlled.
Overvoltage protection: crow bar protection trip off adjusted to 125% of nominal voltage each output
DC Off (trip off): within 5ms if >5% deviation from adjusted nominal values, after overload, overheat, overvoltage, undervoltage (bad status), and fan fail, if temperatures exceed 125°C at heat sinks.
Limits programmable. Outputs discharged by crow bars, when power supply tripped- or switched Off.
Efficiency: 75% ... 85%, depends on used modules 

M F O T (Maintenance Free Operation Time):
internal blowers: 40°C ambient  >65 000 h 
  25°C ambient  100 000 h
electronics: 40°C ambient  >100 000 h 

 

Request a Quote

Learn how W-IE-NE-R products can add power, boost speed and bring rugged durability to your project.

  • This field is for validation purposes and should be left unchanged.