MPOD Mini crate

The Mpod mini crate is the small and low cost option for the WIENER multi-channel high and low voltage power supply system. The Mpod mini mainframe can house up to 4 plug-in low or high voltage modules. The integrated Mpod controller card provides10/100 Ethernet, CAN bus and USB-2 interfaces.

High voltage modules are available with 8 up to 48 channels in the voltage range of 500V ... 20kV. All low voltage modules have 8 channels with a maximum of 50W / channel in different voltage ranges. All HV and LV channels are individually controlled and monitored.

In order to tailor the system to the individual hardware needs Mpod mini can be configured as "low-voltage only", "high voltage only" or "mixed configuration". Local control is available by using the optional LCD display.

Main Features

  • 19" x 5U mini bin with module cage for 4 LV or HV modules, with built-in low noise primary power supply and super-blower ventilation fan 
  • Versions available for HV only, LV only or mixed LV/HV
  • Up to 192 HV channels HV possible /  32 channels low voltage per chassis
  • MPOD controller with Ethernet, USB and CAN-bus interface
  • 19" x 5U mini bin with module cage for 4 LV or HV modules, can be used as desktop, mini tower or rack mountable 
  • Versions available for HV only, LV only or mixed LV/HV
  • 4 slots for modules, LV and HV modules freely combinable
  • Up to 192 channels high voltage possible, ISEG EHS/EDS/EBS modules with 8 … 48 channels in a range of 500V up to 20kV, floating or common ground
  • Up to 32 channels low voltage per chassis, WIENER MPV 8xxx series 8-channel low voltage modules in 0...8V up to 0....120V ranges
  • built in primary power supply (600W), low noise and ripple
  • integrated cooling fan
  • Mpod controller card with Ethernet 10/100, CAN-bus and USB-2 interfaces, Interlock connector, optional with ISEG CC24 controller (linux OS with iCS web service, EPIC's IOC, OPC and SNMP)
  • Integrated web-server and TCP/IP communication via SNMP, OPC server, DHCP capable
  • 94V – 265V world-wide auto-range AC input, with power factor correction, CE-conformity
  • Dimensions: 19” (482mm)  x 4U (178mm) x 480mm [whd], weight: ca. 25 kg
Type  Graphic display  local control Slots Primary  HV-power Output position Backplane supports
Mpod  MINI  No 4 600W Front HV/LV
Mpod  MINI - LX Yes 4 600W Front HV/LV
Mpod  MINI-HV No 4 600W Front HV
Mpod  MINI-HV-LX YES 4 600W Front HV
Mpod  MINI-LV No 4 - Front LV
Mpod  MINI-LV-LX Yes 4 - Front LV
Mpod  MINI basic No 4 300W Front HV+LV
Mpod  MINI-HV basic No 4 300W Front HV
Mpod  MINI-LV basic No 4 - Front LV

 

Specs:  
Rated mains input range 106- 230VAC ± 15% (90...265VAC)
Rated input current Sinusoidal 16A for suffix H input, 32A for suffix K input
Inrush current: limited to rated input current (cold unit)
Input fuse: external, internal on request
Isolation (Inp.- outp.) CE EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950
DC output power:  600 ... <3000W (92 …265VAC)

 

EMC Compatibility    
EMA. EN 61 000-6-3:2001 [RF emission]
  EN 55 022:1998 + Corr:2001 + A1:2000  Class B conducted noise
  EN 55 022:1998+ Corr:2001 + A1:2000  Class B radiated noise
  EN 61 000-3-2:2001 harmonics
  EN 61 000-3-3:1995 +Corr:1997 +A1:2001 flicker
EMB EN 61 000-6-2:2001  [immunity]
  EN 61 000-4-6:1996 + A1:2001 injected HF currents
  EN 61 000-4-3:1996 + A1:1998 + A2:2001 radiated HF fields  incl. ”900MHz”
  EN 61 000-4-4:1995 + A1:2001 Burst
  EN 61 000-4-5:1995 + A1:2001 Surge
  EN 61 000-4-11:1994 + A1:2000 voltage variations
  EN 61 000-4-2:1995 + A1:1998 + A2:2001 ESD

 

Operation temperature:  0… 50°C  ambient without derating,  Storage:-30°C ... +85°C  
Temperature coefficient: < 0,2% / 10K  
Stability:  10mV or 0,1%  /  24 hours, 25mV or 0,3%  /   6 month  
  (under constant conditions)  
Current limits: adjustable to any lower level   
Voltage rise characteristics:  monotonic 50ms, processor controlled.   
Overvoltage protection: crow bar protection trip off adjusted to 125% of nominal voltage  each output
DC Off (trip off):   within 5ms if >5% deviation from adjusted nominal values,
after overload, overheat, overvoltage, undervoltage (bad status),
and fan fail, if temperatures exceed 125°C at heat sinks
Limits programmable. Outputs discharged by crow bars, when power supply tripped- or switched Off. 
Efficiency: 75% ... 85%, depends on used modules    
M F O T (Maintenance Free Operation Time):  
internal blowers: 40°C ambient  >65 000 h 
  25°C ambient  100 000 h
electronics: 40°C ambient  >100 000 h

 

Product Data Sheet  
MPOD Mini crate: Print Product Data Sheet

 

Documentation  
Manual and Tech-Notes : MPOD
Introduction: WIENER_Power_Supplies_intro

 

Downloads  
CD-ROM : MPOD
MUSEcontrol : Download
SNMP: Download
OPC-Server: Download
USB-to-IP: Download
Programming Tool (display): Download
Firmware MPOD: Download

Product Finder

Use our new product finder to locate any item.

Submit