UEL6020-LX fan tray
UEL 6020 LX fan tray is a microprocessor controlled DC-fan box which is plugged into the lower front of the VME 60213 crate. It has an alphanumeric display that can alternatively show power supply voltages, currents, fan speed, output power, temperatures and network parameters (if installed). Further it displays error messages in case of any malfunction of the crate. The fan speed is adjustable between 1200 and 3000 RPM.
designed to provide superior cooling of VME modules in bottom-to-top air flow
2U high with integrated air compression chamber
depth available 160mm, 220mm (3 fans), 280mm, 340mm, 400mm (6 fans or 4 Superblower) and 600mm (9 fans or 6 Superblower)
equipped with individually controlled long-life DC or DC-Superblower fans, MTBF >60 000h
micro-processor controlled with alphanumeric high-visibility LED display, 4 status LED’s
adjustable fan speed (1200 … 3200 RPM)
adjustable “after-running” of fans to provide cooling after power off
integrated fan and thermal monitoring (up to 8 bin temperature sensors) with temperature display (C/K), programmable over temperature protection settings
hot swapping of fan tray programmable
optional with Ethernet / CAN-bus combo interface or CAN-bus interface for crate remote monitoring and control
Technical data:
|
Blower type: |
DC-Standard 1134 574- |
Super Blower - 1450 352 |
|
Dimension: |
118x118mm |
150mm |
|
Static pressure at 3000 RPM: |
8 mm H2O column |
14 mm H2O column |
|
Power Consumption: |
6-8W typical |
12-15W typical |
|
Most efficient operating Range: |
100-160m3/h, 2- 3,8mmH2O |
180-320m3/h, 4- 5,5mmH2O |
|
Speed of Rotation: |
>3000 RPM |
>3000 RPM |
|
Start up Current: |
Limited by soft start circuit |
Limited by soft start circuit |
|
Operating Voltage: |
Fan tray 30VDC, internal Blowers 0-24VDC, |
Fan tray 30VDC, internal Blowers 0-24VDC, |
|
Operating temperature: |
0... 70°C |
0... 70°C |
|
MTBF: |
>65 000 h at 40°C ambient, > 85 000 h at 25°C ambient |
>65 000 h at 40°C ambient, > 85 000 h at 25°C ambient |
|
|
|