• Can-bus option
    • Ethernet option
    • Bin options
    • CAN-CRM
    • Backplane CAMAC
    • Backplane VME-J1
    • Backplane VME-J2
    • Backplane VME/VME64
    • Backplane VME430
    • Backplane VME64x-J1
    • Backplane VME64x
    • Backplane VME64xP
    • Backplane VME64x-430
    • UEV6021-6 bin
    • UEV6021-9 bin
    • UEV6021S-6 bin
    • UEV6021S-9 bin
    • UEV6023-6 bin
    • UEV6023-9 bin
    • UEV6023S-6 bin
    • UEV6023S-9 bin
    • UEL03 / CEL03
    • UEL6020-LX

WIENER Backplanes 3U VME64x J1

The 3U WIENER VME64x-J1 backplane fully complies with ANSI/VITA 1-1994 and IEEE-1014-1987 specifications. It is designed as a 8-layer board in strip-line technolgy. WIENER J1 VME64x backplanes are available with 21 slots (full size).

according to ANSI/VITA 1.1-1997 and 1.3-997. It is designed as a 10-layer board in strip-line technolgy. Monolithic VME64x backplanes are available with 7, 10 or 21 (full size) slots.

The backplane is actively terminated and provides active automatic daisy chaining. On request the active automatic daisy chain is available compatible to the CBLT.

The  extended power layers and special current rails permit highest power distribution. The 21 slot monolithic J1/J2 backplane has more than 300A current capability on 5V, which corresponds to 15A per slot (at 70°C). For power distribution and connection a flat sandwich-like structure of copper sheets is mounted on the back of the upper J1 area. All DC wiring from this high-current multi-layer structure to the power supply situated in the bottom is integrated into the backplane layout by using the space between the connector shrouds.

Backplane Features

  • monolithic FONT 3U WIENER VME64x-J1 backplane,
  • J1 outfitted with 5 row 160-pin connectors
  • 10 layers
  • 21 slots
  • Strip line technology suitable for maximum data rates of (320Mbyte/s, 64bit)
  • Optimized RF shielding
  • Well dispersed filter-capacitors
  • Minimized ground shift and cross talk
  • Automatic daisy chain (electronic)
  • flat cable style connector for sense and control
  • provision for up to 8 temperature sensors (module temp. checking)
  • sense circuit protection by PTC- resistors (Optionally)
  • Excellent power distribution capability by current multi-layer structure
  • maximum power Capabilities (per Slot J1)

Power Distribution  VME64x-J1 backplane per slot / total:  
Voltage Current per slot (20°C / 70°C) Total for 21 slots  (20°C / 70°C)
3,3V 17A / 12A 357A / 252A
5V 8.5A / 6A 187A / 126A
+/-12V 1.7A / 1.2A 35A / 25A
V1, V2 1.7A / 1.2A 35A / 25A
Layers 8/10 8/10

 
 
 