6U VME NIX-I crate series
The low-cost VME NIX-I crate series provides basic VME crates with rear side open frame power supply and removable fan tray.
- 7U VME-Bin VM4 with 21 Slots for 6Ux160mm VME modules,
- 21 slot J1/J2 monolithic backplane, on request with two separated 10 slot backplanes available
- built-in, replaceable VME fan tray UL 4 with high efficient 3- fold DC fan tray blowers, one unit height, air inlet from bottom, optionally watched by temperature sensors and / or variable fan speed
- VME-Power-Supply UEP4, low noise VHF switching technology based, up to 650W output power,
- optionally with CANbus interface (CAN-bus remote monitoring and controlling).
- CE-conformity
|
AC Input |
195...260VAC 47-63Hz, (47-400Hz on request) |
|
Inrush current: |
limited by NTC softstart-circuit, max. 30A (cold unit) |
|
Isolation Inp.-outp.: |
CE , EN 60950, ISO 380, VDE 0805, UL 1950, C22.2.950 |
|
Regulation static: |
5V <25mV (+/-100% load, +/-15% mains) 12V <0.1% (+/-100% load, +/-15% mains) |
|
dynamic : |
5V <100mV (+/-25% load) 12V <0.7% (+/-25% load) |
|
Recovery time : |
+/-25% load within +-1% within +-0.1% 5V 0.2ms 1.5ms 12V 0.0ms 1.0ms |
|
Sense compens.range: |
min. 0.5V with full load |
|
Noise and ripple: |
< 30mVpp (0-20MHz ) 3mVrms (0-2MHz) |
|
EMI /RFI-rejection (emission): |
CE, EN 50081-1 VDE 0871B |
|
EMI / EMC (immunity): |
CE, EN 50082-2 |
|
Operation temp.: |
0....50°C without derating |
|
Storage: |
-30°C up to 85°C |
|
Temp.-coefficient: |
< 0.2% / 10K |
|
Stability (const. conditions): |
10mV or 0.1% within 24 hours 50mV or 1.0% within 6 month |
|
Current limits: |
115% of rated current-values |
|
Overvoltage crow bar protection: |
trip off adjusted to 125% of nominal voltage each output |
|
DC Off (trip off): |
within 5ms if >2% deviation from adjusted nominal values, after overload, overheat, overvoltage, undervoltage (bad status) and fan fail, output capacitors will be discharged by the crow bars temperature limits 110°C heat sink, 70°C ambient, trip off points adjustable, processor controlled. |
|
Efficiency: |
75% - 80% |
|
M T B F: |
>65 000 h (at 40°C ambient temperature) |
| Standard Crate configurations (other possible on request) |
|
|
Crate Version |
+5V |
+/-12V |
-2V |
+/-15V |
+3.3V |
48V |
Power |
|
NIX-I A |
45A |
6.8A/6.8A |
- |
- |
- |
- |
390W |
|
NIX-I B |
100A |
10A/10A |
- |
- |
- |
- |
750W |
|
|
|